SJ4060 Operation Tutorials
Use these videos to set up resin delivery, prepare vision programs and maintain positioning accuracy on SJ4060.
Use these videos to prepare the machine, resin path and operator controls before starting a vision-based job.
Camera Doming Machine Setup Steps
Watch when starting the SJ4060 setup sequence before creating a vision-based dispensing job.
Duration: 2:10
XYZ Movement and Air Venting
Use when checking axis movement and venting air from the resin path during initial setup.
Duration: 6:19
A/B Resin Delivery Calibration
Watch when calibrating the A/B resin component delivery before a production program is confirmed.
Duration: 9:11
Read Step-by-Step GuideVent Air Bubbles from the Mixing Tube
Use when trapped air is present in the mixing tube and the resin path needs venting.
Duration: 7:27
Black Suck-Back Valve Function Adjustment
Watch when reviewing the black suck-back valve response at the dispensing outlet.
Duration: 2:50
Touchscreen Function Introduction
Use before setup to orient yourself to the touchscreen controls used in this workflow.
Duration: 1:22
Use these videos when creating a vision template, copying a prepared job or reviewing speed settings for production.
Dispensing Software Template Creation and Simple Sticker Programming
Watch when creating a software template and programming a simple sticker layout.
Duration: 12:25
Read Step-by-Step GuideCopy a Program File between Two Tables
Watch when transferring a prepared program file from one table to another.
Duration: 2:30
Resin Discharge Speed and Nozzle Moving Speed
Use when reviewing the relationship between resin discharge speed and nozzle movement speed.
Duration: 1:16
Use these videos for routine mixing-tube, anti-curing, heating and low-level alarm tasks around daily production.
Flush the Mixing Tube
Watch after a run or before material remains in the mixing tube for an extended period.
Duration: 2:48
Mixing Tube Anti-Curing Function
Use during a production pause to review the mixing-tube anti-curing function.
Duration: 2:04
Tank Heating Function
Review the tank-heating controls when preparing a resin job that uses this function.
Duration: 1:23
Activate A/B/Cleaning Tank Low-Level Alarm
Use when checking the low-level alarm settings for the A/B and cleaning tanks.
Duration: 0:42
Use these videos when nozzle, camera or reference-plane accuracy needs attention for the current workpiece.
Nozzle Accuracy Calibration
Use after a nozzle or setup change when nozzle-position accuracy needs calibration.
Duration: 3:14
Read Step-by-Step GuideCamera Accuracy Calibration
Watch when vision positioning needs camera-accuracy calibration.
Duration: 9:32
Read Step-by-Step GuideReference Plane Orientation
Use when setting the reference-plane orientation for a vision-coordinate workflow.
Duration: 2:49
Read Step-by-Step GuideWork-Plane Camera Parameter Calibration
Watch when calibrating work-plane camera parameters for an advanced layout.
Duration: 6:56
Read Step-by-Step GuideUse these videos for scheduled system flushing or a confirmed optional stirring-motor configuration.
Flush the System with Acetone
Review the shown system-flush sequence for scheduled cleaning; use the approved cleaning material for your configuration.
Duration: 2:08
Optional Stirring Motor Speed Adjustment
For confirmed optional stirring-motor configurations, review the speed adjustment control.
Duration: 0:39