How to Calibrate A/B Resin Delivery on SJ4060

Use separate five-second weight tests and the matching MCGS A or B calibration factor without changing the approved production ratio.

Browse All Tutorials
Applicable ModelSJ4060 with the shown MCGS resin-control interface
TaskCalibrate A and B delivery by weight
SourceRobota MCGS resin-system operating manual
MCGS resin-control main page showing A, B and A plus B timed dispensing controls
Tap the image to enlarge.

Quick Answer

On the shown MCGS interface, A Spd and B Spd are the target grams delivered by each component in five seconds. They are not volumetric flow values. Keep dynamic mixing off, confirm the correct valve positions, weigh A and B separately, then adjust only the matching calibration factor until actual weight agrees with the approved target. A larger factor increases delivery. Do not change the production A:B weight ratio to compensate for a calibration error.

Before You Start

  • Confirm that the touchscreen matches this tutorial and that the approved A:B weight ratio and A/B five-second targets are documented for the current resin.
  • Prepare separate clean cups, a suitable scale, waste container and required PPE.
  • Before removing the common mixing tube and blade for separate collection, stop the machine and follow the delivered shutdown and safe-pressure-release procedure. Never remove mixing parts while a pump or mixing motor is running.
  • Confirm the equipment has the required air supply, both three-way valves are in the approved open position and dynamic mixing is off.
  • Do not change pump model, acceleration, resin ratio, heating condition or other factory settings during this calibration.

Step-by-Step Procedure

  1. With the common mixing tube and blade safely removed, route A and B into separate clean cups without passing either component through a common mixing chamber or residual mixed material. On the Main Page, set the A and B timed-test fields to exactly five seconds, confirm Mix Tube Off and keep Anti-Cure off during calibration and production setup.
  2. Confirm the valves are in the approved open position. Never close a working three-way valve or obstruct the outlet to create purge pressure.
A and B dispensing valves in the open position for resin calibration
The manual highlights the open position required before separate A and B timed tests.
Tap the image to enlarge.
  1. Tare a clean cup, run Timed Disp. A, allow the final drop to settle and record the actual A weight. Repeat the measurement as needed to separate normal scale variation from a real delivery error.
  2. Compare the actual A weight with the A Spd target in grams per five seconds. Open Params → A/B Qty Calib and adjust only A Calib Factor: increase it to increase delivery or decrease it to reduce delivery.
Collection cup on a digital scale during an A or B resin weight check
Use a tared cup for every reading; the figure shows a single component being weighed.
Tap the image to enlarge.
  1. Repeat A until the readings are stable and agree with the approved target. The source manual notes that three to five weighings are typically sufficient for adjustment.
  2. Use a separate clean cup and repeat the same timed test and factor adjustment for B only.
MCGS A/B Qty Calib screen with separate A Calib Factor and B Calib Factor fields
A and B have separate calibration factors. The displayed numbers are examples, not settings to copy.
Tap the image to enlarge.
  1. After the separate readings are confirmed, stop the machine and follow the same delivered shutdown and safe-pressure-release procedure to reinstall the confirmed mixing blade and tube. Restore the approved production settings and keep the resin ratio unchanged.
  2. Make a controlled A+B discharge into waste and check mixed flow and shut-off before testing one product. If air or abnormal pressure remains, stop and contact Robota rather than forcing a blocked purge.

Completion Checkpoints

  • A and B were measured separately with five-second timed tests.
  • Each component repeats near its own approved gram target.
  • Only the intended A or B calibration factor changed; the production weight ratio did not.
  • The mixer is restored, Anti-Cure is off for production and one waste discharge is stable before product testing.

Stop and Contact Robota When

  • The touchscreen differs from the MCGS interface shown here.
  • The approved ratio, five-second targets or resin compatibility is uncertain.
  • Weights remain unstable after normal priming and repeat checks.
  • A pump, valve, hose or mixer shows leakage, interrupted flow, abnormal pressure, unusual noise or an alarm.

Contact Us

*Your details will be kept strictly confidential with us.